6-50kVA Three Phase Low Frequency Transformer Base UPS Power Supply
Inquire Now
1.IGBT inverter and output isolation transformer
2.Online double conversion
3.Wide input voltage range
4.RS232/RS485 communication port
5.SNMP adapter/dry contact(optional)
6.High reliability and performance
7.External battery pack (optional)
8.Maintenance switch
3B 10kVA-50kVA
Main feature
1.IGBT inverter and output isolation transformer
2.Online double conversion
3.Wide input voltage range
4.RS232/RS485 communication port
5.SNMP adapter/dry contact(optional)
6.High reliability and performance
7.External battery pack (optional)
8.Maintenance switch
Application
1.Data center
2.Industry
3.Commercial facility
4.Telecom system
5.Medical/bank system
6.Precision instrument
Specification
Model |
3B10K |
3B15K |
3B20K |
3B30K |
3B40K |
3B 50K |
Capacity |
10kVA |
15kVA |
20kVA |
30kVA |
40kVA |
50kVA |
Input features |
||||||
Input voltage(Vac) |
380±25% |
|||||
Frequency(HZ) |
45~66 Automatically select synchronization range according to grid frequency |
|||||
Phase |
3φ4W+PE |
|||||
Battery voltage(Vdc) |
192 |
192/384 |
384 |
|||
Output features |
||||||
Power factor |
0.8/0.9 |
|||||
Voltage(V) |
220/230/240±1%,Isolation transformer output |
|||||
Frequency(HZ) |
50/60±0.5%(Free oscillation) |
|||||
Transfer Time(ms) |
0 |
|||||
Waveform |
Sine Wave,THD<3% |
|||||
Overload |
125% load keep 10min,150% load keep 60s |
|||||
Crest factor |
>3:1 |
|||||
Others |
||||||
Output ways |
Terminal Block |
|||||
Parallel function |
Yes(for optional) |
No |
||||
Manual maintenance bypass |
with no transfer time bypass maintenance switch |
|||||
Backup time |
Battery supply life can be configured freely |
|||||
Battery management |
Automatic timing/floating conversion, has battery self-testing function, automatic alarm and judge when battery abnormal |
|||||
Efficiency(AC mode @ full loads) |
≥90% |
|||||
Communication function |
RS232 / RS485 interface, support for power monitor software |
|||||
SNMP(optional) |
Can be network monitored by SNMP adapter |
|||||
Noise (dB) |
<60(within 1 meter) |
|||||
Alarm |
Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection |
|||||
Protection |
Input over-voltage protection, battery under–voltage protection, overload protection, short circuit protection, over temperature protection |
|||||
Working Temperature(℃) |
0~40 |
|||||
Humidity |
0~95%,No Condensing |
|||||
Size(D×W×H) (mm) |
596*305*890 |
700*405*955 (20K:192Vdc)/ 740*560*1200 |
||||
Weight(KG) |
160kg |
200kg |
220kg |
280kg |
340kg |
520kg |
Note:
1, Because the products are continuously improved, please contact the company or dealer to inquiry the latest specification.