Low Frequency Double Conversion Online Transformer Base UPS Power Supply for 1-20kVA
Inquire Now
1.IGBT inverter and output isolation transformer
2.Online double conversion
3.Wide input voltage range
4.RS232 communication port
5.SNMP +USB+dry contact(optional)
6.High reliability and performance
7.External battery pack (optional)
B1kVA-20kVA
Main feature
1.IGBT inverter and output isolation transformer
2.Online double conversion
3.Wide input voltage range
4.RS232 communication port
5.SNMP +USB+dry contact(optional)
6.High reliability and performance
7.External battery pack (optional)
Application
1.Data center
2.Industry
3.Commercial facility
4.Telecom system
5.Precision instrument
Specification
Model |
B1K S/L |
B2K S/L |
B3K S/L |
B4K S/L |
B6K S/L |
B10K S/L |
B15K |
B20K |
|
Capacity |
1KVA |
2KVA |
3KVA |
4KVA |
6KVA |
10KVA |
15KVA |
20KVA |
|
Input features |
|||||||||
Input voltage(Vac) |
165~275 |
||||||||
Frequency(HZ) |
45~66 Automatically select synchronization range according to grid frequency |
||||||||
Phase |
Single phase three wires |
||||||||
Battery voltage(Vdc) |
48 |
96 |
96/192 |
192 |
|||||
Battery type |
4*7Ah 12V/External
|
8*7Ah 12V/External
|
8/16*7Ah 12V/External
|
16*7Ah 12V/External |
External |
||||
Output features |
|||||||||
Power factor |
0.8/0.9 |
||||||||
Voltage(V) |
220/230/240±1% |
||||||||
Frequency(HZ) |
50/60±0.5%(Free oscillation) |
||||||||
Transfer Time(ms) |
0 |
||||||||
Waveform |
Sine Wave,THD<3% |
||||||||
Overload Capacity |
110%~129% full load keep 10min;130%~150% load keep 60s; |
||||||||
Others |
|||||||||
Crest Factor |
>3:1 |
||||||||
Parallel function |
No |
Yes(for optional) |
|||||||
Backup time |
Standard time is 10min/ Long backup time can be extended freely |
||||||||
Charge recovery time |
<10hours |
||||||||
Communication |
RS232(USB/dry contact are optional) |
||||||||
SNMP(Optional) |
Can be network monitored by SNMP adapter |
||||||||
Display |
LED display work status and fault indicator;LCD display single phase input voltage, input frequency, single phase output voltage, load, battery voltage etc |
||||||||
Noise (dB) |
<60(within 1 meter) |
||||||||
Alarm |
Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection |
||||||||
Protection |
Input over-voltage protection, battery under voltage protection, overload protection, short circuit protection, over temperature protection |
||||||||
Working temperature(℃) |
0~40 |
||||||||
Humidity |
0~95%,No Condensing |
||||||||
Size(D×W×H) (mm) |
590*230*717(S)/590*230*540(L)
|
596*305*1065/890 |
700*405*955 |
||||||
Weight(KG) |
80/50 |
99/60 |
107 /52 |
113 /58 |
115 /60 |
160/ 116 |
127 |
195 |
Note:
1、“L” is long backup UPS,“S” is standard UPS;
2、Because the products are continuously improved, please contact the company or dealer to inquiry the latest specification.