CQB2-125 10kA Miniature Circuit Breaker

Inquire Now

Single phase and three phase applications
·High breaking capacity up to 10KA
·Overload protection
·Short circuit protection
·Positive isolation
Suitable for industrial, commercial, high-rise and civil residences circuit protection.

1 Application

·Single phase and three phase applications

·High breaking capacity up to 10KA

·Overload protection

·Short circuit protection

·Positive isolation

Suitable for industrial, commercial, high-rise and civil residences circuit protection.

2 Type designation

Sinoart enterprise content manager system | Sinoart CMS

3 Technical data

Specifications

Rated voltage(V)

AC230V、AC400V

Nominal current (A)

63A、80A、100A、125A

Number of poles

1P 、2P 、3P 、4P

Tripping curves C、D

Rated short-circuit breaking capacity lcu(A)

10000A

Rated service Short-circuit breaking capacity Ics(A)

7500A

Rated impulse withstand voltage Uimp(V)

4000V

Mechanical life(cycles)

≥8000

Electrical life(cycles)

≥1500
Tripping characteristics

table 2

Protection degree

IP20

Standards

IEC60947-2、GB/T14048.2

Compliant certification

CCC

Table2 Tripping characteristics(Reference temp.30℃)

Item Curve Test current ln(A) Initial status Time limit for tripping or non-tripping Expected result Remark
a C、D 1.05ln Cold 1h(ln≤63A)
2h(ln>63A)
Non-tripping Current smoothly rises to specified value within 5s
b C、D 1.3ln Following Item a test 1h(ln≤63A)
2h(ln>63A)
Tripping
c C、D 2ln Cold 1s<t<300s Tripping
d C
D
8ln×80%
12ln×80%
Cold t≤0.2s Non-tripping Switch on the power supply by closing the auxiliary switch
e C
D
8ln×120%
12ln×120%
Cold t<0.1s Tripping Switch on the power supply by closing the auxiliary switch

Note: The terminology “Cold ” means that the test is performed at the base calibration temperature with no load prior to the test.

4 Order Specifications
Sinoart enterprise content manager system | Sinoart CMS

5 cross-sectional area

Rated current Ie Copper cross-sectional area (mm2)
50A<in≤63a< td=”” style=”box-sizing: border-box”> 16
63A<in≤80a< td=”” style=”box-sizing: border-box”> 25
80A<in≤100a< td=”” style=”box-sizing: border-box”> 35
100A<in≤125a< td=”” style=”box-sizing: border-box”> 50

6 Order Specifications
When ordering circuit breakers, the following points should be specified:
A) Product models, such as CQB2-125;
B) Poles of circuit breakers, such as 1P, 2P, 3P, 4P;
C) Types of instantaneous tripping, such as type C and D;
D) Rated current of circuit breakers, such as 63A, 80A, 100A, 125A;
E) Order quantity, e.g. 100 pcs
Purchase order template

CQB2-125 2P C/100A 100pcs

7 Dimensions(unit :mm)

Sinoart enterprise content manager system | Sinoart CMS

Sinoart enterprise content manager system | Sinoart CMS

Product Inquiry Form