C300 Series Inverter

Inquire Now

1.Various voltage levels: support single-phase 220V, three-phase 220V, three-phase 380V, three-phase 480V, three-phase 520V, three-phase 690V, three-phase 1140V voltage levels and so on.
2.Various control modes: support vector control with speed sensor (FVC), vector control without speed sensor (SVC), V/F control mode and V/F separation mode control.
3.Various field bus: support Modbus-RTU and other communication modes.
4.Various encoder types: support differential encoder, open collector encoder, rotary transformer encoder, UVW encoder and other encoder types.
5.New control algorithm of vector control without speed sensor (SVC): it has better low-speed stability and higher low-frequency torque carrying capacity, and supports SVC torque control at the same time.
6.Support user programming: users can realize secondary development by using the user programming expansion card.

C300 Series Inverter

Standard Features:

  1. 1.Various voltage levels: support single-phase 220V, three-phase 220V, three-phase 380V, three-phase 480V, three-phase 520V, three-phase 690V, three-phase 1140V voltage levels and so on.

  2. 2.Various control modes: support vector control with speed sensor (FVC), vector control without speed sensor (SVC), V/F control mode and V/F separation mode control.

  3. 3.Various field bus: support Modbus-RTU and other communication modes.

  4. 4.Various encoder types: support differential encoder, open collector encoder, rotary transformer encoder, UVW encoder and other encoder types.

  5. 5.New control algorithm of vector control without speed sensor (SVC): it has better low-speed stability and higher low-frequency torque carrying capacity, and supports SVC torque control at the same time.

  6. 6.Support user programming: users can realize secondary development by using the user programming expansion card.

  7. 7.Rich function extension:

A. virtual input/output IO;

B. Motor overheat protection can support PT100 and PT1000 sensors;

C. Fast current limiting can solve frequent over-current faults in inverters;

D. Multi-motor parameter switching;

E. Input and output of AI/AO analog quantity with higher accuracy;

F. Fault handling mode is optional;

G. PID process control parameter switching;

H. PID process control feedback loss detection;

I. PID process control can be used for positive and negative logic selection and response delay setting;

J. Timing operation and PLC operation setup cycle or single operation.

8. Conform to the following instructions and standards:

A. EMC instruction conforms to EN61800-3, EN55011, EN61000-6-2 standards;

B. LVD instruction conforms to EN61800-5-1 standards.

Technical Specifications

Items

Specifications

Basic functions

The highest frequency

0~500Hz

The carrier frequency

0.5~16KHz, which can be automatically adjusted according to the load characteristics

Input frequency resolution

Digital input: 0.01hz analog input: highest frequency ×0.025%

Control mode

Open-loop vector SVC, closed-loop vector FVC, V/F control

Starting torque

G type SVC 0.5Hz/150%;FVC 0Hz/180%

P type SVC 0.5Hz/100%

Speed adjustment range

1:100 SVC

1:1000 FVC

Speed stabilization precision

±0.5% SVC

±0.02% FVC

Torque control precision

±5% FVC

Overload capacity

G type 150%Ie 60s 180%Ie 3s

P type 120%Ie 60s 150%Ie 3s

Torque lifting

Automatic or manual( manual range: 0.1%~30.0%)

Basic functions

V/F curve

Straight line, multi-point and N th-power (1.2/1.4/1.6/1.8/2.0 power) optional

Acceleration and deceleration curve

Straight line and S-shaped curve are optional, and four acceleration and deceleration time can be adjusted within 0.0~6500.0s

DC braking

Braking start frequency: 0.00Hz~ max frequency

Braking time: 0.0~36.0s

DC braking injection current setting: 0.0~100.0%Ie

Inching control

Frequency is 0.00~50.00Hz, and the acceleration and deceleration time is 0.0~6500.0s

Simple PLC and multi-speed operation

Through the built-in PLC or DI terminal can achieve a maximum of 16 speed operation

The built-in PID process control

Easy to realize the process closed-loop control

Automatic voltage adjustment (AVR)

Can automatically keep the production voltage constant when the input voltage changes

Enhancements

Over-voltage, over-current stall control

Automatic control in the operational process, to avoid inverter frequently jump over-voltage and over-current faults

Fast current limiting function

Minimize over-current fault and ensure reliable operation of inverter

Torque limitation and control

Automatically limit torque during operation, FVC can realize torque control

Product Inquiry Form