10-200kVA Three Phase Low Frequency Over Temperature Protection Online UPS Power Supply
Inquire Now
1.IGBT inverter and output isolation transformer
2.Manual maintenance bypass switch
3.Wide input voltage range
4.RS232/RS485/dry contact communication port
5.SNMP adapter (optional)
6.Fully DSP control and high reliability and performance
7.3 phase UPS allow 100% unbalanced load
8.EPO function(optional)
9.7 inches touchable LCD screen(optional)
3B3 10kVA-120kVA
Main feature
1.IGBT inverter and output isolation transformer
2.Manual maintenance bypass switch
3.Wide input voltage range
4.RS232/RS485/dry contact communication port
5.SNMP adapter (optional)
6.Fully DSP control and high reliability and performance
7.3 phase UPS allow 100% unbalanced load
8.EPO function(optional)
9.7 inches touchable LCD screen(optional)
Application
1.Data center
2.Industrial equipment
3.Commercial facility
4.Telecom system
5.Medical/bank system
6.Precision instrument
Specification
Model |
3B3 10K |
3B3 15K |
3B3 20K |
3B3 30K |
3B3 40K |
3B3 60K |
3B3 80K |
3B3 100K |
3B3 120K |
Capacity |
10 KVA |
15 KVA |
20 KVA |
30 KVA |
40 KVA |
60 KVA |
80 KVA |
100 KVA |
120 KVA |
Input features |
|||||||||
Input voltage(Vac) |
380±25% |
||||||||
Frequency(HZ) |
40—70Hz Automatically select synchronization range according to grid frequency |
||||||||
Bypass synchronous range (Hz) |
50/60±5%(±10% for optional) |
||||||||
Phase |
3φ4W+PE |
||||||||
Battery voltage(Vdc) |
384 |
||||||||
Battery quantity(Pcs) |
30-34 can be set
|
||||||||
Output features |
|||||||||
Power factor |
0.8/0.9 |
||||||||
Voltage(Vac) |
L-N:220/230/240±1% L—L:380/400/415±1% |
||||||||
100% three-phase load unbalanced voltage stability |
≤2%,allow 100% unbalanced |
||||||||
Frequency(HZ) |
Mains normal,same as mains frequency;Mains abnormal,50±0.2% |
||||||||
Transfer Time(ms) |
0 |
||||||||
Efficiency(AC mode @ full loads) |
≥92% |
||||||||
Parallel function |
Yes(for optional) |
||||||||
Waveform |
Linear Load THD<3%;Non-linear Load THD<5% |
||||||||
Overload capacity |
125% full load keep 10min;150% full load keep 1min; |
||||||||
Crest Factor |
>3:1 |
||||||||
Others |
|||||||||
Manual maintenance bypass |
with no transfer time bypass maintenance switch |
||||||||
Communication function |
RS232 / RS485/dry contact |
||||||||
SNMP(optional) |
Can be network monitored by SNMP adapter |
||||||||
Noise (dB) |
<65(within 1 meter) |
||||||||
Alarm |
Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection |
||||||||
Protection |
Input over-voltage protection, battery under–voltage protection, overload protection, short circuit protection, over temperature protection |
||||||||
Cooling way |
Forced cooling |
||||||||
Working Temperature(℃) |
0~40 |
||||||||
Humidity |
0~95%,No Condensing |
||||||||
EMC |
GB7260.2 |
||||||||
Size(D×W×H) (mm) |
730*380*1320 |
730*555*1210 |
740*810*1410 |
745*1420*1810 |
|||||
Weight(KG) |
160 |
180 |
220 |
240 |
320 |
440 |
520 |
820 |
940 |
Note: