3/3 Three Phase Low Frequency Online Transformer Base UPS Power Supply for 60-600KVA
Inquire Now
1.IGBT inverter and output isolation transformer
2.Manual maintenance bypass switch
3.Wide input voltage range
4.RS232/RS485/dry contact communication port
5.SNMP adapter (optional)
6.Fully DSP control and high reliability and performance
7.3 phase UPS allow 100% unbalanced load
8.EPO function(optional)
9.7 inches touchable LCD screen
3B3GX 60K-600K
Main feature
1.IGBT inverter and output isolation transformer
2.Manual maintenance bypass switch
3.Wide input voltage range
4.RS232/RS485/dry contact communication port
5.SNMP adapter (optional)
6.Fully DSP control and high reliability and performance
7.3 phase UPS allow 100% unbalanced load
8.EPO function(optional)
9.7 inches touchable LCD screen
Application
1.Data center
2.Industrial equipment
3.Commercial facility
4.Telecom system
5.Medical/bank system
6.Precision instrument
Specification
Model |
3B3 GX 60K |
3B3 GX 80K |
3B3 GX 100K |
3B3 GX 120K |
3B3 GX 160K |
3B3 GX 200K |
3B3 GX 250K |
3B3 GX 300K |
3B3 GX 400K |
3B3 GX 500K |
3B3 GX 600K |
Capacity |
60 kVA |
80 kVA |
100 kVA |
120 kVA |
160 kVA |
200 kVA
|
250 kVA
|
300 kVA
|
400 kVA
|
500 kVA
|
600 kVA
|
Input features |
|||||||||||
Pulse rectifier |
6 pulse |
6/12 pulse |
12 pulse |
||||||||
Voltage range(Vac) |
380/400/415Vac±15%(±25%) |
||||||||||
Frequency range(HZ) |
40—70Hz Automatically select synchronization range according to grid frequency |
||||||||||
Phase |
3φ4W+PE |
||||||||||
Battery voltage(Vdc) |
384 |
||||||||||
Battery quantity(Pcs) |
30-34 can be adjusted |
30-34 can be adjusted |
|||||||||
Output features |
|||||||||||
Power Factor |
0.8/0.9 |
||||||||||
Voltage(V) |
L-N:220/230/240±1% L—L:380/400/415±1% |
||||||||||
Frequency(HZ) |
Mains normal,track mains frequency;Mains abnormal,50±0.2% |
||||||||||
Transfer time(ms) |
0 |
||||||||||
Efficiency(AC mode @ full loads) |
≥92% |
||||||||||
Parallel function |
Yes(for optional) |
||||||||||
Waveform |
Linear Load THD<3%;Non-linear Load THD<5% |
||||||||||
Overload |
125% load keep 10 min,150% load keep1min |
||||||||||
Peak Factor |
>3:1 |
||||||||||
Others |
|||||||||||
Manual maintenance bypass |
with no transfer time bypass maintenance switch |
||||||||||
Communication function |
RS232 / RS485/dry contact |
||||||||||
SNMP(optional) |
Can be network monitored by SNMP adapter |
||||||||||
Noise (dB) |
<65(within 1 meter) |
||||||||||
Alarm |
Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection |
||||||||||
Protection |
Input over-voltage protection, battery under–voltage protection, overload protection, short circuit protection, over temperature protection |
||||||||||
Cooling way |
Forced cooling |
||||||||||
Working Temperature(℃) |
0~40 |
||||||||||
Humidity |
0~95%,No Condensing |
||||||||||
Size(D×W×H) (mm) |
800*800*1600(6 pulse)/1100*800*1800(12 pulse) |
1100*800*1800 |
1405*1113*2005 |
1605*1113*2005 |
2600*1100*2000 |
||||||
Weight(T) |
0.48 |
0.56 |
0.89 |
1.08 |
1.28 |
1.38 |
1.68 |
1.98 |
2.48 |
2.85 |
3.15 |
Note:
1, Because the products are continuously improved, please contact the company or dealer to inquiry the latest specification.