GTM1-400-3p/4p Moulded Case Circuit Breaker MCCB with IEC60947-2

Inquire Now

GTM1 Mould Case Circuit Breaker
1-OEM Service Offered
2-Payment : LC/TT
3-Delivery : By sea / By train
4-FOB/CIF/CIP

Application: In distribution network of AC50Hz or 60Hz, ranted voltage up to 690V and rated insulation voltage 800V
Standard: IEC60947-2
Parameters: Rated voltage: 400V, 690V
Rated current: 6-2000A
Rated insulation voltage: 800V
Features: High breaking capacity
Reasonable design, safe and reliable.
Compact conformation, Elegant appearance
Easy to install, better adaptability.
With 2, 3, 4 poles.

Model GTM1-63 GTM1-125 GTM1-250 GTM-400 GTM1-630 GTM1-800
IEC60947-2 GB/T 14048.2
Shell grade current Inm(A) 63 125 250 400 630 800
Operating frequency(Hz) (Hz) 50 50 50 50 50 50
Breaking type L M L M L M L M L M L M
Number of poles 3P 3P,4P 2P,3P 2P,3P,4P 2P,3P 2P,3P,4P 3P 3P,4P 3P 3P,4P 3P,4P 3P
Rated current In(A) 10~63 16~125 100~250 225,250,315,350,400 400,500,630 630,700,800
Rated isnulation voltage Ui(V) 500 800 800 800 800 690
Rated impulse withstand voltage Uimp(V) 8 8 8 8 8 8
Rated working voltage Ue(V) 400 230/400 230/400/690 230/400 230/400/630 400 400/690 400 400/690 400
Flashover distance (mm) ≯50 ≯50 ≯50 ≯100 ≯100 ≯100
Rated ultimate short-circuit sgementation capability Icu(kA) 400V 25 50 35 50 35 50 50 65 50 65 50 65
690V 20(3P) 20(3P) 20(3P) 20(3P)
Rated running short-circuit segementation capability Ics(kA) 400V 12.5 35 25 35 25 35 35 50 35 50 35 45
690V 10(3P) 10(3P) 15(3P) 15(3P)
Utilization category A A A A A A
Service life Mechanical life(times) Free maintenance 20000 20000 20000 10000 10000 10000
Maintenance 40000 40000 40000 20000 20000 20000
Mechanical life(times) 8000 8000 8000 7500 7500 7500
Outline dimension Width(W)(2P*/3P/4P) 78 78,103 65,92 65,92,122 75,107 75,107,142 150 150,198 181 181,239 210,280 210
Length(L) 135 150 165 258 270 280
Height(H) 89 96 86 104 106 124 150 155 158
Opitonal Accessories
Alarm contact 08 O O O O O O
Shunt release 10 O O O O O O
Auxiliary contacts 20 O O O O O O
Under-voltage tripper 30 O O O O O O
Two groups of auxiliarycontact 60 O O O O O O
Direct rotation handle RH O O O O O O
Extended rotation handle ERH O O O O O O
Hand-operated mechanism SC1 O O O O O O
Electrical operation mechanism MT O O O O O O
Mechanical interlocking MIF O O O O O O
Wiring in front of the plate O O O O O O
Plug-in back-panel wiring O O O O O O
Plug-in front-panel wiring O O O O O
Draw-out type O O O

O Optional – None *only GTM1-125 and GTM1-250 have 2P


10.jpg



12.jpg幻灯片1.JPG

Product Inquiry Form