Ac servo motor driver 100w-7.5kw

Inquire Now

have normal type driver . also have better quality type driver . have 220v .and 380v driver

SG-AS series servo motor drives

Performance parameters


Control mode Position control, JOG operation, speed contacts, etc.
Encoder feedback Ordinary incremental encoder: 2500 lines incremental standard type 2500 line incremental province-wire serial encoder: 217/216 bit absolute encoder
Conditions of Use Ambient temperature / storage temperature Ambient temperature: 0 ~ + 50 ℃, Storage temperature: -20 ~ + 85 ℃
Humidity / storage humidity 90% RH or less (no freezing or condensation)
Resistance to vibration / impact resistance 4.9m/s2/19,6m/s2
Structure Base mount
Performance Speed control range 1:10000(Lower limit of the speed control range is the smooth operation at rated load without crawling)
Speed response 1KHz
Rate volatility (load variation) 0 to 100% load; 0% (rated speed)
Rate volatility (voltage variation) Rated voltage ± 10%: 0% (rated speed)
Rate volatility (temperature variation) 25 ± 25 ℃: ± 0.1% or less (rated speed)
Analog speed command input Command voltage DC±10V
Input impedance Approximately20KΩ
Circuit time parameter 47 μ s
Analog torque command input Command voltage DC±10V
Input impedance

约20KΩ

Circuit time parameter 47 μ s
Sequence input signal Count 8Point
Function (distribution) Servo ON (/ S-ON), P action (/ P-CON), prohibits Story side driving (P-OT), prohibiting reverse side driving (N-OT), alarm reset () / ALM-RST, positive Zhuance torque limit (/ P-CL), reverse the measured torque limit (/ N-CL), the position deviation is cleared (/ CLR), the internal set speed switching can be allocated and the signal of the positive / negative logic change
Sequence output signal Count 6Point
Function (distribution) Servo alarm () ALM positioning completion (/ COIN) consistent speed detection (/ V-COMP) servo motor rotation detection (/ TGON) Servo ready (/ S-RDY), torque limit detection (/ CLT) Brakes (/ BK) encoder zero output (PGC) can be assigned as well as the positive / negative logic of the signal change
Encoder Dividing pulse output A phase, B phase, C: linear drive output; divider pulses: can be arbitrarily set
RS-485Communications Protocol MODBUS
1:N Communication Can be up to N = 127 station
Axis address setting By parameter setting
CANCommunications Protocol CANOpen (DS301 + DS402 profile)
1:NCommunication Can be up to N = 127 station
Axis address setting By parameter setting
Display Function CHARGE LED, 7-segment 5
Regeneration treatment Built-in regenerative resistor or external regenerative resistor (optional)
Overtravel (OT) prevention function P-OT、N-OT Enter the action of dynamic brake (DB) stop, deceleration stop or free-run stop
Protection Overcurrent, overvoltage, undervoltage, overload, speeding, regeneration fault, encoder feedback error, etc.
Monitoring functions Speed, current position, command pulse accumulation, position deviation, motor current, operating status, input and output signals
Accessibility Features Gain adjustment, alarm recording, JOG operation, origin search, inertia testing
Smart features Built-in automatic gain tuning function
Use load inertia Less than 5 times of motor inertia
Position control Feedforward compensation 0~100%(Setting unit 1%)
Input pulse types Sign + pulse train, CW + CCW pulse train, 90 ° phase difference between the two-phase pulse (A phase + B phase)
Input pulse form Supports linear drive, open collector
Maximum input pulse frequency

Linear drive

Sign + pulse train, CW + CCW pulse sequence: 500K pps

90 ° phase difference between the two-phase pulse (A phase + B-phase): 500K pps

Open Collector

Sign + pulse train, CW + CCW pulse sequence: 200K pps

90 ° phase difference between the two-phase pulse (A phase + B-phase): 200K pps