CNSX Moulded Case Circuit Breaker
Inquire NowDescription
The CNSX Moulded Case Circuit Breaker (MCCB) is engineered for high performance and reliability, offering exceptional protection for electrical circuits. With over 30 years of industry experience, we deliver high-quality MCCBs at competitive prices, making this product ideal for dealers, wholesalers, and various clients seeking dependable circuit protection solutions.
This circuit breaker features a robust design that ensures effective overload and short-circuit protection. The CNSX range is customizable, providing options for manual control, multiple connection types, and a variety of performance characteristics to meet the demands of modern electrical installations.
Key characteristics include an adjustable overload setting, advanced time delay options, and comprehensive electrical specifications aligning with IEC60947 and EN60947-2 standards. The CNSX MCCB stands out with its versatility and enhanced safety features, making it an essential component for secure electrical management.
Specifications
Item No. | CNSX100-250 | CNSX400-630 | |
---|---|---|---|
Number of poles | 3P, 4P | ||
Control | Manual | with toggle / with direct or extended rotary handle | |
Connections | Fixed | front connections | |
Plug-in | front connections/rear connections | ||
Electrical characteristics as per IEC60947 and EN60947-2 | |||
Rated current (A) | In | 16, 25, 32, 40, 50, 63, 80, 100, 125, 160, 200, 250 | 400, 500, 630 |
Rated insulation voltage (V) | Ui | 800 | |
Rated impulse withstand voltage (kV) | Uimp | 8 | |
Rated operational voltage (V) | Ue | AC 50/60Hz, 690 | |
Utilization category | A | ||
Breaking capacity levels | F, N, H | ||
Breaking capacity (kA rms) AC 50/60 Hz 380/415 V | lcu | 36, 50, 70 | |
Service breaking capacity (kA rms) AC 50/60 Hz 380/415 V | lcs | 36, 50, 70 | |
Operation performance | Mechanical | 20000 | 10000 |
Electrical | 10000 | 5000 | |
Protection | Chart B-1 B-2 | ||
Indication and control auxiliaries | |||
Auxiliary switch | ■ | ||
MX Shunt coil | ■ | ||
MN under-voltage coil | ■ |
Additional Information
Overload Protection: Equipped with thermal overload protection based on a bimetal strip that trips the circuit breaker when the temperature limit is exceeded. The adjustable current setting ranges from 0.7 to 1 times the trip unit rating (16A to 250A), allowing for tailored protection.
Short-Circuit Protection: Features magnetic protection that triggers instantaneous tripping for excessive current. The fixed pick-up settings cater to ratings from 16A to 160A, with adjustable options available for higher ratings.