Diesel Generator PERKINS 1200kW Open Type
Inquire NowDescription
The Diesel Generator PERKINS 1200kW Open Type is a robust and reliable power solution designed for various industrial applications. Powered by the efficient PERKINS engine, this generator delivers exceptional performance with a prime power output of 1250 kVA (1000 kW) and standby power of 1375 kVA (1100 kW). Ideal for both temporary and permanent installations, it is built to withstand harsh conditions while ensuring consistent power delivery.
This generator operates at a voltage of 400 V / 230 V and a frequency of 50Hz with a speed of 1500 RPM. The design features a 12-cylinder V configuration with a 4-stroke cycle, ensuring powerful and efficient performance. With a compression ratio of 13:1 and a displacement of 45.842 liters, the PERKINS engine provides robust torque and efficiency.
Specifications
Specification | Details |
---|---|
Model | R-P1250 |
Prime Power | 1250 kVA / 1000 kW |
Standby Power | 1375 kVA / 1100 kW |
Voltage | 400 V / 230 V |
Frequency / Speed | 50Hz / 1500 RPM |
Power Factor | 0.8 |
Ambient Temperature | 40 °C |
Altitude | 1000 m |
Connection Type | 3 Phase, 4 Wires |
ENGINE | |
Brand / Model | Perkins / 4012-46TWG2A |
Prime Power / Standby Power | 1106 kW / 1217 kW |
No. of Cylinders / Alignment | 12 / V |
Cycle | 4 Stroke |
Bore / Stroke | 160 mm / 190 mm |
Displacement | 45.842 L |
Governing | Electronic |
Cooling | Water |
Fuel Consumption (100% Load) | 301 L/h |
ALTERNATOR | |
Brand / Model | STAMFORD / PI734C |
Rated Capacity | 1550 kVA |
Rated Power | 1240 kW |
AVR Model | MX341 |
Voltage Regulation (No Load- Full Load) | ± 1.0% |
THF(BS EN60034 – 1) | <2% |
Underspeed Protection | Standard |
Protection | IP23 |
Windings | 100% Copper |
Additional Information
For optimal performance, regular maintenance is recommended. Ensure that the generator is operated within its specified temperature and altitude limits to prolong its lifespan. Always follow safety guidelines during operation and maintenance.