The NT3000 Diesel Injection Pump Test Bench is a cutting-edge device designed to measure and analyze the performance of diesel injection pumps with precision and efficiency. This advanced test bench serves multiple functions, including the measurement of cylinder delivery at various speeds, testing the oil supply angle of injection pumps, and checking mechanical governors. With features that enable the adjustment of distributor pumps and electromagnetic valves, this test bench is essential for ensuring optimal performance in diesel engines.
Engineered for high measurement precision, the NT3000 boasts capabilities such as frequency change in rotational speed, low fall in rotational speed, and high output torque. It also includes safety features like over-voltage, overload, and short circuit protection, making it a reliable choice for professionals. The test bench supports multiple rotation speed presets, operates quietly, and features a built-in air resource for added convenience.
Specifications
No. | Items | Data |
---|---|---|
1 | Main motor output power (kw) | 7.5KW / 11KW / 15KW / 18.5KW |
2 | Frequency Converter | ZHONGCHEN |
3 | Stroke Counting (Rpm) | 0-9999 |
4 | Standard injectors | ZS12SJ1 |
5 | Power of fuel pump motor (kw) | 0.75 |
6 | Scope of rotate speed (r/m) | 0~4000 |
7 | Number of cylinders | 12 |
8 | Height of principal axis center (mm) | 125 |
9 | Filter oil precision of test bench (μ) | 4.5~5.5 |
10 | Volume of big and small volume cylinder (ml) | 150 / 45 |
11 | Volume of fuel tank (L) | 60 |
12 | DC power supply | 12/24V |
13 | Feeding pump motor | 1.1kw |
14 | Low pressure of fuel oil pressure (Mpa) | 0~0.4 |
15 | High pressure of fuel oil pressure (Mpa) | 0~4 |
16 | Pressure Gauge for VE Pump (Mpa) | 0-1.6 |
17 | Pressure Gauge for VE Pump (Mpa) | 0-0.16 |
18 | Control temperature of fuel (℃) | 40 ± 2 |
19 | Flywheel inertia (kg*m) | 0.8~0.9 |
20 | Scope of rack bar stroke (mm) | 0~25 |
21 | Measuring range of flow meter (L/m) | 10~100 |
22 | DC electrical source (V) | 12 / 24 |
23 | Positive pressure of air supply (Mpa) | 0~0.3 |
24 | Negative pressure of air supply (Mpa) | -0.03~0 |
25 | Dimension of Packing (L*W*H(m)) | 2.1*1.1*1.72 |
26 | Gross weight of Test bench (kg) | 650 |