Description
The Fire Fighting Equipment Emergency Power Supply is a reliable and efficient single-phase UPS designed to meet the demanding needs of critical applications. With a capacity range of 0.5 to 15kW, this UPS ensures that your essential systems remain operational during power outages. Its wide input voltage range and cutting-edge digital control technology enhance performance, making it ideally suited for harsh grid conditions and industrial environments.
Designed with a high IP level, this UPS is equipped to withstand challenging conditions, while its robust overload capacity and strong anti-interference abilities ensure continuous functionality. With user-friendly network management features, this UPS is perfect for vital applications including traffic systems, industrial equipment, steel factories, and fire fighting equipment.
Specifications
| EPS | ||
|---|---|---|
| Model | YJ series | YJS series |
| Capacity range | 0.5KW-10KW | 2.2KW-800KW |
| Input voltage | three phase 380V/single phase 220V ±25% | 380±20% |
| Input Phase | three phase four wires/single phase two wires | three phase four wires +Ground |
| Input frequency | 50HZ±5% | 50HZ±5% |
| Output voltage | 220±5% | 380V/220V±5% |
| Output waveform | sinewave, distortion≤3% | sinewave, distortion≤3% |
| Output frequency | 50HZ±5% (emergency response time) | 50HZ±5% (emergency response time) |
| Transfer time | <0.2s | <100ms |
| Waveform | sine wave (emergency response time) | sine wave (emergency response time) |
| same as the mains at normal times | same as the mains at normal times | |
| Emergency supply time | 90 minutes (for optional) | 60/90/120 minutes (for optional) |
| Overload capacity | working normal with 120% load | |
| Protection | battery overcharging and discharging, output under voltage, over current, short circuit and over temperature protection | battery overcharging and discharging, output under voltage, over current, short circuit, lack of phase and over temperature protection |
| Display | LCD | |
| Noise | no noise in mains mode, <55dB in emergency supply time | no noise in mains mode, <60dB in emergency supply time |
| Relative humidity | 0-90%, no condensing | 0-90%, no condensing |
| Temperature | -24℃-40℃ | -24℃-40℃ |
| Altitude | under 2000m | under 2000m |
Additional Information
- Ideal for use in traffic systems, industrial settings, and steel factories.
- Ensures dependable performance under harsh conditions.
- Can be integrated into fire fighting equipment effectively.