Impulse Pressure Test Bench

Inquire Now

Oil system test stand:
It is a impulse test stand designed mainly for powered steering tube, brake hose, air conditioning tube, fuel tube, condenser, evaporator, oil cooler, steel pipe, Bundy pipe and other devices that use hydraulic oil, ATF oil, mineral oil, brake oil or fuel as the circulation medium. It is a comprehensive performance test stand integrating control of high/low frequency, multiple waveforms, medium temperature and ambient temperature into a whole.
Gas impulse test stand:
This test stand can be used for gas pressure alternating test of such products as air intercooler, turbo-charging hose and Nylon hose, using high temperature compressed air as the testing medium. It is controlled by industrial computer, and has a Chinese interface for testing parameter inputting. It allows real-time monitoring and control, as well as air-tightness check before and during the test.

Oil system test stand:

Ranges of technical parameters:

Scope of application

Rubber cooling water tube, metal cooling water tube, radiator, ventilation core, heater, etc

Applicable standards

QC/T468GB/T18948TL52361GMW14329DIN73411JISD2602D321WH-A(HONDA), and so on.

Range of pressure

0-2Mpa,allowing arbitrary selection.

Range of impulse frequency

0-3Hz,allowing arbitrary selection.

Setting range of number of tests

0-10,000,000 times

Range of ambient temperature

-50-200,allowing arbitrary selection; Control manner: “fixed value control” and “alternating control” of temperature, allowing selection.

Range of medium temperature

-50-200, allowing arbitrary selection

Range of testing mediums

water, glycol, brake fluid, etc

Range of vibration modes

Electromagnetic vibration (including scanning and vertical vibration), mechanical vertical vibration, servo vibration, mechanical rotation vibration.

Installation manner

Hose connection, straight line connection, adjustable fixture connection

Quantity of tested products

2-10 channels

Gas impulse test stand

Ranges of technical parameters:

Scope of application

Intercooler, turbo-charging hose, Nylon tube and testing pieces using compressed air as medium.

Applicable standards

QC/T 828GMW15803GMW16153 etc.

Range of pressure

0-2MPa, allowing arbitrary selection.

Range of impulse frequency

0-2Hz, allowing arbitrary selection.

Setting range of number of tests

0-10,000,000 times

Range of ambient temperature

-50-200℃,allowing arbitrary selection; Control manner: “fixed value control” and “alternating control” of temperature, allowing selection.

Range of medium temperature

Room temperature-300℃, allowing arbitrary selection.

Range of testing mediums

Air

Range of vibration modes

Electromagnetic vibration (including scanning and vertical vibration), mechanical vertical vibration, servo vibration.

Installation manner

Hose connection, straight line connection, adjustable fixture connection

Quantity of tested products

2-10 channels

Related Products

Product Inquiry Form