Inquire NowThe PR203 Sel Thermal Compressor Protector Motor Protection Relay is a cutting-edge device engineered to consistently monitor 3-phase power lines for any abnormal conditions. This versatile relay is suitable for motors of any size or type. Upon detecting a motor fault that exceeds the preset alarm threshold, the PR203 promptly activates the release switch to shut down the circuit, ensuring optimal safety and performance. With an optional RS485 communication port, users can effortlessly upload monitoring data and alarm statuses to a remote control system, enhancing operational efficiency.
Features
- Cost-effective electronic design relay that can replace various single-function protection relays.
- Compatible with motors under 0.66KV.
- Integrated 3P CT for current sampling, suitable for currents under 200A.
- Two digital outputs for external control loops.
- Optional RS-485 network communications.
- Optional earth leakage sensor or analog output available.
- Optional ground fault detection.
- Equipped with an LCD display for easy monitoring.
Application
- Compatible with or without a zero-sequence core-balance current transformer.
- Can be used with or without an external RTD module.
- Suitable for across-the-line and star-delta starting methods.
- Ideal for two-speed motors.
Electrical Parameters | Details |
---|---|
Auxiliary Power | 85-265Vac/dc |
Power Consumption | <4 VA |
Insulation Resistance | >100MΩ |
Relays | 5A/250VAC, 5A/30VDC (NO contact) |
Motor Rated Voltage | AC220V / AC380V / AC660V |
Motor Rated Current | 0.5-200A use internal CT 200A-820A use external ../5A CT |
Leakage Current Sensor | 0-1A |
Impulse Withstand Voltage | 4 kV |
Measuring Accuracy: Current | ± 0.5% @ 10~120% Ie |
Measuring Accuracy: Voltage | ± 0.5% @ 10~150% Ue |
Measuring Accuracy: Frequency | ± 0.1% @ 45~65Hz |
Measuring Accuracy: Power Factor | ± 1% @ 0.0~1.0 |
Measuring Accuracy: Power | ± 1% @ 0~500 kW |
Measuring Accuracy: Temperature | ± 1% @ 0.1~30 K |
Analog Output | ± 1% (4 ~ 20mA) |
Comm Port | RS485 MODBUS-RTU |
Digital Input | Regular 6DI, max11 DI |
Digital Output | Regular 3DO, max 6DO |
SOE | 10 |
Working Temperature | -10C ~ +55°C |
Storage Temperature | -30C ~ +70°C |
Relative Humidity | < 93% RH |
Elevation | Less than 3000 m |
Standard Reference | IEC 60947-1, IEC 60947-4 |
Electrostatic Discharge | Severity: level III |
Surge | Severity: level III |
Voltage Characteristics | Between two of the power/input/output between AC2kV/1min |