Synchronization Control System
Inquire NowDescription
The APS Synchronization Control System is a cutting-edge technology developed by AOSIF that expertly manages the synchronization of multiple generators in parallel while ensuring efficient load sharing. This highly integrated and compact system utilizes imported synchronization panels, making it both user-friendly and powerful. Equipped with comprehensive monitoring capabilities, the system keeps track of essential electrical and dynamic parameters, providing a robust level of protection for your equipment.
Key monitored parameters include:
- Speed
- Oil pressure
- Water temperature
- Battery voltage
- Three-phase voltage, current, and frequency
- Load active power, reactive power, and power factor
Additionally, the system ensures protection against various faults such as:
- Over voltage, under voltage, over current, short circuit, and reverse power
- Speed, oil pressure, water temperature, and battery voltage faults
Specifications
Generator Power | Circuit Breaker Capacity | Synchronization Panel | Chinese Circuit Breaker | MOLLER Circuit Breaker | Schneider Circuit Breaker | ABB Circuit Breaker | Busbar Size for Circuit Breaker | Copper Busbar Size for 2 Units | Cabinet Size (L*W*H mm) |
---|---|---|---|---|---|---|---|---|---|
P≤125KW | 250A | DSE 8610 | XKM1-250S/R250 | LZMB2-A250 | NSX250F-250D | T3N250TMD R250 FF | 25*3 mm | 4×40 mm | 800×800×1700 |
125KW < P≤200KW | 400A | DSE 8610 | XKM1-400S | LZMC3-A400 | NSX400F-400A | T5N400TMA R400 FF | 40*3 mm | 6×50 mm | 800×800×1700 |
200 < P≤318KW | 630A | DSE 8610 | XKM1-630S | LZMN3-AE630 | NSX630F-630A | T6N630 TMA R630 FF | 50*4 mm | 6×80 mm | 800×800×1700 |
318 < P≤400KW | 800A | DSE 8610 | XKM1-800S | NZMN4-AE800 | NS800N-800A | T6N800 TMA R800 FF 3P | 60*6 mm | 10×80 mm | 800×800×1800 |
400 < P≤500KW | 1000A | DSE 8610 | XKM1-1000S | NZMN4-AE1000 | NS1000N-1000A 2.0 | T7S1000M PR231/PLSI R1000 FF | 60*8 mm | 10×100 mm | 800×800×1800 |
500 < P≤630KW | 1250A | DSE 8610 | XKW1-1600/1250 | IZM91B3-V12CF | NS1250N-1250A 2.0 | T7S1250M PR231/P-LSI R1250 FF | 60*10 mm | 10×120 mm | 800×800×1800 |
630 < P≤800KW | 1600A | DSE 8610 | XKW1-1600/1600 | IZM91B3-V16CF | NS1600N-1600A | T7S1600M PR231/P-LSI R1600 FF | 80*10 mm | 2(10×100) mm | 1000×1000×1800 |
800 < P≤1000KW | 2000A | DSE 8610 | XKW1-2000/2000 | IZM97B3-A20CF | MT20N-2000A 2.0 | E2B2000 R2000 PR121/P-LI | 2(80*6) mm | 2(10×120) mm | 1000×1000×2200 |
1000 < P≤1250KW | 2500A | DSE 8610 | XKW1-3200/2500 | IZM97B3-A25CF | MT25N-2500A 2.0 | E3N2500 R2500 PR121/P-LI | 2(80*8) mm | 2(10×150) mm | 1000×1000×2200 |
1250 < P≤1600KW | 3200A | DSE 8610 | XKW1-3200/3200 | IZM97B3-A32CF | MT32N-3200A 2.0 | E3N3200 R3200 PR121/P-LI | 2(100*10) mm | 3(10×150) mm | 1000×1000×2200 |
Additional Information
For optimal performance and longevity, it is recommended to regularly monitor the system’s parameters and perform maintenance checks as per the guidelines provided. Proper care will help ensure the synchronization system operates efficiently, minimizing downtime and enhancing reliability.