Thermostat

Inquire Now

Professional, accurate and cheap

Model

Operating Temperature

LIMITED

Capillary

mm

Foece OFF

WARM

NORMAL

COLD

FORCE ON

ON

OFF

ON

OFF

ON

OFF

WPF0.5A-EX

10±2

6.7±2

3.5±1.5

-0.5±1.5

330

Operating Temperature

Way naming of thermostat

W

1

2

3

4

5

6

For example:WDF21A-K-EX

W——-thermostat.

1——-Model: P-common type, D-constant temperature and replacement type, Y- high temperature type.QS- Maual reset, M-the type of DAMPER THERMOSTAT

2——-When the temperature of cold (low) cut is over 0 ℃, no expression, otherwise it is expressed with “F”

3——-The absolute value of the temperature of cole (low) opened (OFF).

4——-Design series revised, indicated by Chinese spelling order A,B,C…

5——-K-K type of RANCO,A-A type of RANCO,D-the type of DANFOSS,L-the type of SAGNOMIYA.

6——-S-defrosting thermostat, X-signal thermostat, Ex-explosion-proof thermostat

Principle

The pressure of working medium in bellows, caplillary and sensor will varied with the temperature in the controlled object. The expression of bellows makes the bar to move via a lever and so the mini-switch works ON and OFF.

  1. Far from vibration. Radius of capillary should be more than 20mm.The sensor must be impressed 150mm at least by varied temperature at the one trolled object.

  2. The temperature in the controlled range could be made with turning the cam,i.e., the temperature goes down with clockwise and goes up with counter clockwise. All the screws on the thermostat have been sealed.

  3. Pressing the defrost button when it needs defrost button when it needs defrosting, and then the refrigeration stops when defrosting. When the temperature rises to the lever, the thermostat resetting automatically and returning to work accordingly.

  4. Turning the cam to a position for a force-off thermostat when the refrigerator equipment needs to be stopped temporarily. The power should be cut off if stopping working for a long time.

THE SWITCH

The arrow indicates the temperature rising; The sign C.L.H,3.4.6 are terminals; C.L. is the terminal of the SAGINOMYA type;3.4.6 is the terminal of RANCO type.

Electric Date

Rating Voltage———- 250V(AC250V)

Frequency———————50Hz/60Hz

Rating Current———–5(4)A

the temperature arrange that can be adjusted—– -36– +350

The temperature condition that can be used: TSTB

TS: The temperature about main body of productions

TB:The temperature about detector of production

Voltage

Current

Power

High Current

Middle Current

Small Current

AC125/250

AC125

AC250

AC125

AC250

noninductive load

1

1-16

1-8

0.5-5

inductive load

Normal

0.75

1-16

1-6

0.5-4

0.02-2

0.02-1

Starting

0.45

1-64

1-24

0.5-16

0.02-8

0.02-4

Terminals

250#

250# 205# 187#

250# 205# 187#

Meaning in marks

ON-turn on OFF-turn off

W-warm position DIF-difference

Ts-medium temperature for main body

Tb-temperature for temperature-sense compartment

C-Cold position Def-Defrosting

N-Normal position

Supply Ability:

10000 Carton/Cartons per Month

Product Name

K series thermostat

Voltage(V)

250V

Contact Resistance

Below 50 Ω

Life Cycle

100,000times

Rated Current

10A 250VAC/15A 250VAC

Switch Type

Hight/low pressure switch

Available Temp Range

-20~+20°C

Adjustable Temp Range

Max 16°C

Full open to full close diff

8~150°C

Packing Size

<span style=font-family:”inherit”,”

Product Inquiry Form